loading

Professional Intelligent Manufacturer of High and Low Voltage DC Contactors - Aokai Electric

Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 1
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 2
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 3
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 4
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 5
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 6
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 1
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 2
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 3
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 4
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 5
Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current 6

Top Aokai Electric Dc Motor Reversing Contactor for Switching DC Current

Inquiry

Features

Continuous 400A load.

It has two sets of normally open and two sets of normally closed contacts.

Coil power consumption ≤20W.

The insulation resistance is up to 100MΩ (1,000VDC), the withstand voltage between the contact and the coil is 1kV.

IP protection level: IP40.

Compliant with IEC 60664-1, GB/T14048.1 and GB/T14048.4 requirements.

Compliant with RoHS (2015/863/EU), REACH (1907/2006/EC) requirements.

Safety certificate: CE.

ASW400-2Z-02

Specification

Performance Parameters (at 23)

Contact Arrangement

2K (2NO), 2B (2NC)

Contact Resistance

≤0.5mΩ

Contact Voltage Drop

≤80mV (at 400A)

Overload Current

≤7le, ≯1s

Temperature Range

-25℃~60℃

Load Terminal

M10 External Thread

Humidity

20%~90%RH

External Dimension

160.5mmx72mmx153mm

Operating Duty

Continuous

Electrical Durability with Load (Resistive)

≥6,000 Times

Load Wiring Torque

10-13N.m

Pull-In Voltage

≤70% Us

Drop-Out Voltage

≥10% Us

Contact Bounce Period

≤5ms

Pull-In Time

≤30ms

Drop-Out Time

≤30ms

Dielectric Strength

Between Main Contacts

50Hz/60Hz 1,000VAC/1min

Between Main Contacts and Coil

50Hz/60Hz 1,000VAC/1min

Insulation Resistance

Initial State

100MΩ 1min

After Electrical Life

50MΩ 1min

Shock

(60-100) times/min, Acceleration<4g

Vibration

3.5g, 10~200Hz, 1/2 Sine Wave (Power On)

Mechanical Durability

≥100,000 Times

Coil Wiring 

0.8*6.3 Spade Terminal

ASW400S2Z Coil Parameters

Coil Voltage

Pull-In Voltage

Drop-Out Voltage

Holding Current

Coil Power Consumption (Holding)

12V

≤70%Us

≥10%Us

≤1.50A

<20W

24V

≤70%Us

≥10%Us

≤0.70A

36V

≤70%Us

≥10%Us

≤0.50A

48V

≤70%Us

≥10%Us

≤0.35A

60V

≤70%Us

≥10%Us

≤0.30A

72V

≤70%Us

≥10%Us

≤0.25A

Product Introduction

This series DC Contactor is used to control the motor reversing, which is widely used in electromobiles, electric forklifts, electric winches, engineering machinery, etc.

ASW400-2Z-09
ASW400-2Z-09
ASW400-2Z-08
ASW400-2Z-08
ASW400-2Z-05
ASW400-2Z-05
ASW400-2Z-03
ASW400-2Z-03

Model Coding

图片 1 (11)

Wiring Diagram

图片 2 (11)

Outline Installation Dimension Drawing

图片 3 (11)
图片 3 (11)
图片 4 (10)
图片 4 (10)


Company Advantages

· The production technology of Aokai Electric dc motor reversing contactor has been greatly improved by our dedicated R&D team.

· We are striving forward to try to achieve the great performance of dc motor reversing contactor to make it more practical for customers.

· Zhejiang Aokai Electric Co., Ltd upholds the most professional and most responsible service concept.


Company Features

· Zhejiang Aokai Electric Co., Ltd offers the best dc motor reversing contactor at the best price. We are able to personalize our products in a unique style.

· We have cultivated a team of experts. They demonstrate strong skills and knowledge in yield analysis and improvement, product engineering, packaging, and overall production flow logistics.

· Dedication to customer success is a core value that affects everything we do. We quickly react to customers and their needs and make regular communication with customers, which helps us close gaps between customer expectations and our services.


Application of the Product

Aokai Electric's dc motor reversing contactor can meet the different needs of customers.

We are committed to meeting the need of our customers. We will go deeper into their situation and provide them with most suitable solutions.

Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.
no data

Professional Intelligent Manufacturer of High and Low Voltage DC Contactors.


READ MORE>

CONTACT US
Contact: Richard Zhang
TEL: 0086 577 62779591
MOB: 0086 13968752095
WhatsApp: 0086 13968752095
Company Address: No.166 Xiangbai Road, Huxi Industrial Park, Liushi Town, Yueqing City, Zhejiang Province, 325600 P.R.China
Copyright © 2025 Zhejiang Aokai Electric Co., Ltd | Sitemap
Customer service
detect